Staff Publications

Staff Publications

  • external user (warningwarning)
  • Log in as
  • language uk
  • About

    'Staff publications' is the digital repository of Wageningen University & Research

    'Staff publications' contains references to publications authored by Wageningen University staff from 1976 onward.

    Publications authored by the staff of the Research Institutes are available from 1995 onwards.

    Full text documents are added when available. The database is updated daily and currently holds about 240,000 items, of which 72,000 in open access.

    We have a manual that explains all the features 

Record number 452204
Title De Next Generation Semigesloten Kas : Perspectief van een ontvochtigingssysteem op basis van een koeloppervlak en
Author(s) Zwart, H.F. de; Speetjens, S.L.
Source Wageningen UR Glastuinbouw (Rapport / Wageningen UR Glastuinbouw 1292) - 52
Department(s) GTB Tuinbouw Technologie
Publication type Research report
Publication year 2013
Keyword(s) glastuinbouw - semi-gesloten kassen - verwarmingssystemen - geconditioneerde teelt - kastechniek - ontvochtiging - duurzaamheid (sustainability) - greenhouse horticulture - semi-closed greenhouses - heating systems - conditioned cultivation - greenhouse technology - dehumidification - sustainability
Categories Horticulture / Greenhouse Technology
Abstract Het nieuwe concept Next Generation Semigesloten kas is met recht een opvolger van eerdere generaties (semi)gesloten kassen. Het systeem realiseert een substantiële invulling van de verwarming van kasteelten met duurzame warmte. Het concept is gebaseerd op een kleine aanpassing van de luchtbehandelingskasten die met de opkomst van Het Nieuwe Telen in steeds meer kassen te zien zijn. Door deze luchtbehandelingskasten naast een verwarmend blok ook met een koelblok uit te rusten kan met een beperkte luchtcirculatie (10 m³/(m² uur)) de kas in de winter meer gesloten gehouden worden door de kas intern te ontvochtigen. In de zomer kan dezelfde installatie worden gebruikt om, net als in de eerdere generaties (semi) gesloten kassen, energie te verzamelen uit het zomerse warmteoverschot ten behoeve van de voeding van een warmtepomp in de winter. Het systeem is in de praktijk getest in een kasafdeling van 3680 m². Uit deze proef bleek dat in de gegeven kas de warmtebehoefte van 40 m³/(m² jaar) voor 25% met duurzame warmte kon worden ingevuld. De benodigde investeringen leiden bij de huidige gasprijs tot een simpele terugverdientijd van ruim 7½ jaar. The Next Generation Semi Closed Greenhouse is an improved version of earlier generations of (semi) closed greenhouses. The system provides renewable energy for the heating of greenhouses. The concept is based on an optimised utilisation of the air treatment units that have become widespread with the ‘New Cultivation’ in greenhouses. In this New Cultivation greenhouses, dehumidification is performed by a well-controlled inlet and even distribution of outside air. In the Next Generation Semi Closed greenhouse, the air treatment units are furbished with a cooling heat exchanger in the upstream air flow next to the heating block. The air circulation capacity is around 10 m³/ (m² h ). With the cold heat exchanger, the greenhouse can be internally dehumidified. This enables to keep the windows shut during the cold period of the year, which prevents losses of sensible and latent heat. In summer, the same system can be used for gathering heat from the summertime heat surpluses to provide energy for wintertime use of a heat pump. These summertime heat surpluses are stored in an aquifer system, just like the common practice in previous generations of (semi) closed greenhouses. The system was tested on 3680 m² of a commercial greenhouse and compared in terms of energy consumption with a standard greenhouse operation. The experiments showed that at the system could provide a 25% contribution of sustainable energy in the heat demand. At current energy prices the simple payback time of the investments for a Next Generation Semi Closed greenhouse will be around 7 ½ years. Besides this system, the study also analysed the perspectives of hygroscopic dehumidification. It showed to be a realistic dehumidification system for modern greenhouses. The energy saving potential of hygroscopic dehumidification is likely to be even higher than that of a system based on condensation on a cold surface. The economic outlook depends largely on the price of the regenerator, the machine that extracts the water out of the desiccant solution. Behalve het Next Generation systeem op basis van een koelblok is ook gekeken naar de perspectieven van een hygroscopisch ontvochtigingssysteem op basis van een CaCl2-oplossing. Het energiebesparingspotentieel van hygroscopische ontvochtiging ligt waarschijnlijk iets hoger dan dat van een systeem op basis van een koelblok. Het economische perspectief hangt voornamelijk af van de prijs van de regenerator, de machine die de verdunde zoutoplossing weer moet indikken met terugwinning van de latente warmte.
Comments
There are no comments yet. You can post the first one!
Post a comment
 
Please log in to use this service. Login as Wageningen University & Research user or guest user in upper right hand corner of this page.